KEW 8130 sensor measures up to 1000A AC current and is flexible and lightweight by the air core coil used at the sensor part. Designed to meet the international safety standard IEC 61010-1 CAT IV 300V, CAT III 600V.
Specification
Conductor size | max.Ø110mm |
---|---|
Rated current | AC 1000A |
Output voltage | AC 500mV / 1000A (AC 0.5mV/A) |
Accuracy | ±0.8%rdg±0.2mV (45Hz to 65Hz) ±1.5%rdg±0.4mV (40Hz to 1kHz) |
Phase shift | within ±2.0° (45Hz to 65Hz) |
Cable length | Approx. 3m |
Output connector | MINI DIN 6PIN |
Output impedance | 100Ω or less |
Applicable standards | IEC 61010-1 , IEC 61010-2-030 IEC 61010-2-032 CAT IV 300V / CAT III 600V Pollution degree 2 IEC 61326 |
Operating temperature and humidity range | -10 to 50°C , relative humidity 85% or less (no condensation) |
Weight | Approx. 180g |
Accessories | 9095 (Carrying case) Instruction manual , Cable marker |