Kyoritsu 6516 Multi Function Tester

Features

  • Continuity test
  • Insulation resistance test
  • Loop impedance test (High current measurement, No trip (ATT) measurement) 4 Prospective short circuit current test (On Loop impedance function)
  • RCD test
  • Voltage test
  • Phase rotation test 8 Earth test

Kyoritsu 6516 Multi Function Tester

The KEW 6516 tester incorporates Anti Trip Technology (ATT) which electronically bypasses RCDs when performing loop impedance tests. This saves time and money by not having to take the RCD out of the circuit during testing and is a safer procedure to follow.

With the ATT function enabled, a test of 15mA or less is applied between line & earth. It enables loop impedance measurements without tripping RCDs rated at 30mA and above.

ATT supports measurements using three wires: Line, Earth, and Neutral and also two wires: Line and Earth.

Specification

Insulation resistance SPD
(Varistor)
Test voltage 100V 250V 500V 1000V Max.1000V
Measuring ranges 2.000/20.00/200.0MΩ
(Auto-ranging)
20.00/200.0/
1000MΩ
(Auto-ranging)
20.00/200.0/
2000MΩ
(Auto-ranging)
0 to 1049V
(goes up by 1V)
Accuracy ±2%rdg±6dgt
(2.000/20.00MΩ)
±5%rdg±6dgt
(200.0MΩ)
±2%rdg±6dgt
(20.00/200.0MΩ)
±5%rdg±6dgt
(1000MΩ)
±2%rdg±6dgt
(20.00/200.0MΩ)
±5%rdg±6dgt
(2000MΩ)
±5%rdg±5dgt
Rated current 1.0 to 1.2mA
@0.1MΩ
1.0 to 1.2mA
@0.25MΩ
1.0 to 1.2mA
@0.5MΩ
1.0 to 1.2mA
@1MΩ
Output short circuit current 1.5mA max
Loop impedance
Function LOOP ATT LOOP HIGH
L-PE/L-N
(3wire)
L-PE
(2wire)
L-PE
(0.01ΩRes)
L-PE
(0.001ΩRes)
High test current
(25A)
L-N/L-L
Rated voltage 100 to 260V
(50/60Hz)
48 to 260V
(50/60Hz)
48 to 260V
(50/60Hz)
100 to 260V
(50/60Hz)
48 to 500V
(50/60Hz)
Impedance range 20.00/200.0/2000Ω
(Auto-ranging)
20.00/200.0/2000Ω
(Auto-ranging)
2.000Ω 20.00Ω
Accuracy ±3%rdg±6dgt ±3%rdg±10dgt ±3%rdg±4dgt ±3%rdg±25mΩ ±3%rdg±4dgt
Nominal test current at 0Ω external
loop: Magnitude/ Duration at 230V
L-N:6A/60ms
N-PE:10mA
L-PE:15mA 20Ω:
6A/20ms
200Ω:
0.5A/20ms
2000Ω:
15mA/500ms
25A/20ms 6A/20ms
PSC/PFC
Range 2000A/20kA
(L-N(PSC)/L-PE(PFC))
2000A/20kA
(PFC)
2000A/20kA
(PFC)
2000A/50kA
(PFC)
2000A/20kA
(PSC)
Accuracy PSC/PFC accuracy is derived from measured loop impedance specification and measured voltage specification
RCD
Rated voltage 100 to 260V(50/60Hz)
Function x1/2, x1,x5,Ramp,Auto,Uc
6/10/30/100/300/500/1000mA/variable
RCD type AC(G/S) A(G/S) F(G/S) B(G/S) EV
Trip current setting x1/2,
x1,Uc
10/30/100/300/
500/1000mA(G)
10/30/100/
300/500(S)
10/30/100/
300/500mA
10/30/100/
300/500mA
10/30/100/
300mA
6mA
(x1 only)
x5 10/30/100mA 10/30/100mA 10/30/100mA 10/30mA
Ramp 10/30/100/
300/500mA
10/30/100/
300/500mA
10/30/100/
300/500mA
10/30/100/
300mA
6mA
Accuracy Trip
current
x1/2 -8 to -2% -10 to 0% -10 to 0% -10 to 0%
x1 +2 to +8% 0 to +10% 0 to +10% 0 to +10% 0 to +10%
x5 +2 to +8% 0 to +10% 0 to +10% 0 to +10%
Ramp -4 to +4% -10 to +10% -10 to +10% -10 to +10% -10 to +10%
Trip
time
x1/2 2000ms(G/S):±1%rdg±2ms
x1 550ms(G):±1%rdg±2ms,1000ms(S):±1%rdg±2ms 10.5s:±1%±2㎳
x5 410ms(G/S):±1%rdg±2ms
Continuity
Range 20.00/200.0/2000Ω (Auto-ranging)
Open circuit voltage(DC) 7 to 14V
Measuring
current
200mA 200mA or more(2Ω or less)
15mA 15mA±3mA(short-circuit)
Accuracy ±2%rdg±8dgt
Volts
Range 300.0/600V(Auto-ranging)
Measuring
ranges
Volts 2 to 600V
Frequency 45 to 65Hz
Accuracy Volts ±2%rdg±4dgt
Frequency ±0.5%rdg±2dgt
Phase Rotation
Rated voltage 48 to 600V(45 to 65Hz)
Remarks Remarks Correct phase sequence: are displayed “1.2.3” and mark
Reversed phase sequence: are displayed “3.2.1” and mark
Earth
Range 20.00/200.0/2000Ω(Auto-ranging)
Accuracy ±2%rdg±0.08Ω(20.00Ω)
±2%rdg±3dgt(200.0/2000Ω)
General
Applicable standards IEC 61010-1 CAT IV 300V / CAT III 600 V Pollution degree 2
IEC 61010-2-034, IEC 61557-1,2,3,4,5,6,7,10
IEC 60529(IP40), IEC 61326(EMC)
Power source LR6 (AA) (1.5V) ×8
Communication interface USB
Dimension / Weight 136(L) × 235(W) × 114(D) mm / 1350g (including batteries)
Accessories Mains test lead※1
7281 (Test leads with remote control switch)
7246 (Distribution board test lead)
7228A (Earth resistance test leads)
8041 (Auxiliary earth spikes[2 spikes/1 set])
9084 (Soft case)
9142 (Carrying case)
9151 (Shoulder strap)
9199 (Shoulder pad)
8212-USB (USB adapter)
LR6(AA) × 8
Instruction manual
Calibration certificate
Optional Accessories 8259 (Adapter for measurement terminal)
7272 (Precision measurement cord set)
8017A (Extension prod long)
8602 (EVSE ADAPETER)

Reviews

There are no reviews yet.

Be the first to review “Kyoritsu 6516 Multi Function Tester”

Your email address will not be published. Required fields are marked *