Kyoritsu 6516 Multi Function Tester
The KEW 6516 tester incorporates Anti Trip Technology (ATT) which electronically bypasses RCDs when performing loop impedance tests. This saves time and money by not having to take the RCD out of the circuit during testing and is a safer procedure to follow.
With the ATT function enabled, a test of 15mA or less is applied between line & earth. It enables loop impedance measurements without tripping RCDs rated at 30mA and above.
ATT supports measurements using three wires: Line, Earth, and Neutral and also two wires: Line and Earth.
Specification
Insulation resistance | SPD (Varistor) |
||||||
---|---|---|---|---|---|---|---|
Test voltage | 100V | 250V | 500V | 1000V | Max.1000V | ||
Measuring ranges | 2.000/20.00/200.0MΩ (Auto-ranging) |
20.00/200.0/ 1000MΩ (Auto-ranging) |
20.00/200.0/ 2000MΩ (Auto-ranging) |
0 to 1049V (goes up by 1V) |
|||
Accuracy | ±2%rdg±6dgt (2.000/20.00MΩ) ±5%rdg±6dgt (200.0MΩ) |
±2%rdg±6dgt (20.00/200.0MΩ) ±5%rdg±6dgt (1000MΩ) |
±2%rdg±6dgt (20.00/200.0MΩ) ±5%rdg±6dgt (2000MΩ) |
±5%rdg±5dgt | |||
Rated current | 1.0 to 1.2mA @0.1MΩ |
1.0 to 1.2mA @0.25MΩ |
1.0 to 1.2mA @0.5MΩ |
1.0 to 1.2mA @1MΩ |
‐ | ||
Output short circuit current | 1.5mA max | ‐ | |||||
Loop impedance | |||||||
Function | LOOP ATT | LOOP HIGH | |||||
L-PE/L-N (3wire) |
L-PE (2wire) |
L-PE (0.01ΩRes) |
L-PE (0.001ΩRes) High test current (25A) |
L-N/L-L | |||
Rated voltage | 100 to 260V (50/60Hz) |
48 to 260V (50/60Hz) |
48 to 260V (50/60Hz) |
100 to 260V (50/60Hz) |
48 to 500V (50/60Hz) |
||
Impedance range | 20.00/200.0/2000Ω (Auto-ranging) |
20.00/200.0/2000Ω (Auto-ranging) |
2.000Ω | 20.00Ω | |||
Accuracy | ±3%rdg±6dgt | ±3%rdg±10dgt | ±3%rdg±4dgt | ±3%rdg±25mΩ | ±3%rdg±4dgt | ||
Nominal test current at 0Ω external loop: Magnitude/ Duration at 230V |
L-N:6A/60ms N-PE:10mA |
L-PE:15mA | 20Ω: 6A/20ms 200Ω: 0.5A/20ms 2000Ω: 15mA/500ms |
25A/20ms | 6A/20ms | ||
PSC/PFC | |||||||
Range | 2000A/20kA (L-N(PSC)/L-PE(PFC)) |
2000A/20kA (PFC) |
2000A/20kA (PFC) |
2000A/50kA (PFC) |
2000A/20kA (PSC) |
||
Accuracy | PSC/PFC accuracy is derived from measured loop impedance specification and measured voltage specification | ||||||
RCD | |||||||
Rated voltage | 100 to 260V(50/60Hz) | ||||||
Function | x1/2, x1,x5,Ramp,Auto,Uc | ||||||
6/10/30/100/300/500/1000mA/variable | |||||||
RCD type | AC(G/S) | A(G/S) | F(G/S) | B(G/S) | EV | ||
Trip current setting | x1/2, x1,Uc |
10/30/100/300/ 500/1000mA(G) 10/30/100/ 300/500(S) |
10/30/100/ 300/500mA |
10/30/100/ 300/500mA |
10/30/100/ 300mA |
6mA (x1 only) |
|
x5 | 10/30/100mA | 10/30/100mA | 10/30/100mA | 10/30mA | – | ||
Ramp | 10/30/100/ 300/500mA |
10/30/100/ 300/500mA |
10/30/100/ 300/500mA |
10/30/100/ 300mA |
6mA | ||
Accuracy | Trip current |
x1/2 | -8 to -2% | -10 to 0% | -10 to 0% | -10 to 0% | – |
x1 | +2 to +8% | 0 to +10% | 0 to +10% | 0 to +10% | 0 to +10% | ||
x5 | +2 to +8% | 0 to +10% | 0 to +10% | 0 to +10% | – | ||
Ramp | -4 to +4% | -10 to +10% | -10 to +10% | -10 to +10% | -10 to +10% | ||
Trip time |
x1/2 | 2000ms(G/S):±1%rdg±2ms | – | ||||
x1 | 550ms(G):±1%rdg±2ms,1000ms(S):±1%rdg±2ms | 10.5s:±1%±2㎳ | |||||
x5 | 410ms(G/S):±1%rdg±2ms | – | |||||
Continuity | |||||||
Range | 20.00/200.0/2000Ω (Auto-ranging) | ||||||
Open circuit voltage(DC) | 7 to 14V | ||||||
Measuring current |
200mA | 200mA or more(2Ω or less) | |||||
15mA | 15mA±3mA(short-circuit) | ||||||
Accuracy | ±2%rdg±8dgt | ||||||
Volts | |||||||
Range | 300.0/600V(Auto-ranging) | ||||||
Measuring ranges |
Volts | 2 to 600V | |||||
Frequency | 45 to 65Hz | ||||||
Accuracy | Volts | ±2%rdg±4dgt | |||||
Frequency | ±0.5%rdg±2dgt | ||||||
Phase Rotation | |||||||
Rated voltage | 48 to 600V(45 to 65Hz) | ||||||
Remarks | Remarks Correct phase sequence: are displayed “1.2.3” and mark Reversed phase sequence: are displayed “3.2.1” and mark |
||||||
Earth | |||||||
Range | 20.00/200.0/2000Ω(Auto-ranging) | ||||||
Accuracy | ±2%rdg±0.08Ω(20.00Ω) ±2%rdg±3dgt(200.0/2000Ω) |
||||||
General | |||||||
Applicable standards | IEC 61010-1 CAT IV 300V / CAT III 600 V Pollution degree 2 IEC 61010-2-034, IEC 61557-1,2,3,4,5,6,7,10 IEC 60529(IP40), IEC 61326(EMC) |
||||||
Power source | LR6 (AA) (1.5V) ×8 | ||||||
Communication interface | USB | ||||||
Dimension / Weight | 136(L) × 235(W) × 114(D) mm / 1350g (including batteries) | ||||||
Accessories | Mains test lead※1 7281 (Test leads with remote control switch) 7246 (Distribution board test lead) 7228A (Earth resistance test leads) 8041 (Auxiliary earth spikes[2 spikes/1 set]) 9084 (Soft case) 9142 (Carrying case) 9151 (Shoulder strap) 9199 (Shoulder pad) 8212-USB (USB adapter) LR6(AA) × 8 Instruction manual Calibration certificate |
||||||
Optional Accessories | 8259 (Adapter for measurement terminal) 7272 (Precision measurement cord set) 8017A (Extension prod long) 8602 (EVSE ADAPETER) |
Reviews