Kyoritsu 3128 High Voltage Insulation Tester

Key features: Kyoritsu 3128 Digital 12 kV Insulation Tester

• Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions.
• Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc.
• 6 ranges: 500V, 1000V, 2500V, 5000V, 10000V, 12000V
Fine adjustment of voltage setting at each range is also possible
• Graphic representation of the insulation resistance and leakage current versus time on large display with bar graph and backlight.
• Can be operated from built-in rechargeable battery or from AC line.
• Automatic discharge after test with monitoring of the discharge voltage.
• Internal memory can store about 43,000 data (max).
• Robust design for field use with IP64 rating (with lid closed).

Category:

Kyoritsu 3128 High Voltage Insulation Tester

The Kyoritsu 3128 is a digital CAT IV High Voltage Insulation Tester subsequent to the capabilities of psychiatry insulation resistance taking place to 35T, once test voltages going on to 12kV. The 3128 model is meant for arena use when an IP64 rating and features a large LCD display taking into consideration backlight.

The Kyoritsu 3128 is a microprocessor-controlled high voltage insulation resistance tester, following various logical functions. Such functions meet the expense of the take absorb to test the polarization index (PI), the dielectric absorption ratio (DAR) and the dielectric discharge (DD). Step voltage (SV) measurements can be applied, where successive voltage increments are implemented, to test the degradation of insulation. Insulation resistance can be measured occurring to 35T when test voltages going on to 12kV using this instrument.

Specification

Insulation resistance
Test voltage 500V 1000V 2500V 5000V 10000V 12000V
Max measurement value 500GΩ 1TΩ 2.5TΩ 5TΩ 35TΩ
Accuracy 400kΩ to 50GΩ
±5%rdg±3dgt
800kΩ to 100GΩ
±5%rdg±3dgt
2MΩ to 250GΩ
±5%rdg±3dgt
4MΩ to 500GΩ
±5%rdg±3dgt
8MΩ to 1TΩ
±5%rdg±3dgt
50.1 to 500GΩ
±20%rdg(*)
101G to 1TΩ
±20%rdg
251G to 2.5TΩ
±20%rdg
501GΩ to 5TΩ
±20%rdg
1.01 to 10TΩ
±20%rdg
10.1 to 35TΩ
Short circuit current Max 5.0mA
Load resistor to output rated voltage 0.5MΩ or more 1MΩ or more 2.5MΩ or more 5MΩ or more 20MΩ or more 24MΩ or more
Output voltage
Rated voltage 500V 1000V 2500V 5000V 10000V 12000V
Monitor accuracy ±10%±20V
Output accuracy 0 to +20% 0 to +10% -5 to +5%
Selectable range 50 to 600V
(in steps of 5V)
610 to 1200V
(in steps of 10V)
1225 to 3000V
(in steps of 25V)
3050 to 6000V
(in steps of 50V)
6100 to 10000V
(in steps of 100V)
10100 to 12000V
(in steps of 100V)
Voltage measurement
Measuring range DCV:±30 to ±600V
ACV:30 to 600V (50/60Hz)
Accuracy ±2%rdg±3dgt
Current measurement
Measuring range 5.00nA to 2.40mA
(Depending on the insulation resistance)
Accuracy ±5%rdg±5dgt
Capactince measurement
Measuring range 5.0nF to 50.0μF 40.0nF to 1.00μF
(Display range : 5.0nF to 60.0μF)
Accuracy ±5%rdg±5dgt
General
Applicable standards IEC 61010-1 CAT IV 600V Pollution degree 2, IEC 61010-2-034,
IEC 61010-031, IEC 61326, IEC 60529 (IP64): with the lid closed.
Operating temperature and humidity range -10ºC , Relative humidity 85% or less 50ºC /(when operating with an external power supply, no condensation)
0 to 40ºC /Relative humidity 85% or less (when operating with battery, no condensation)
Storage temperature and humidity range -20ºC to 60ºC / Relative humidity 75% or less (no condensation)
Power source Rechargeable Lead storage battery (12V)* Charging time: approx. 8 hours / AC Power supply (100V to 240V, 50/60Hz)
* Continuous measuring time: Approx. 4 hours (a load of 100MΩ at the Insulation resistance 12000V Range.)
Approx. 2 hours (Max current consumption in range while rated currents are maintained.)
Dimension 330 (L) × 410 (W) × 180 (D) mm *Instrument and Hard case
Weight Approx. 9kg (including battery) *Instrument and Hard case
Accessories 7170 (Power cord[EU]) or 7240 (Power cord[UK])
7224A (Earth cord)
7225A (Guard cord)
7226A (Line probe)
7227A (Line probe with alligator clip)
8029 (Extension prod)
8212-USB (USB adapter)
Instruction manual
Optional accessories 7254 (Longer Line probe with alligator clip)

Reviews

There are no reviews yet.

Be the first to review “Kyoritsu 3128 High Voltage Insulation Tester”

Your email address will not be published. Required fields are marked *