Kyoritsu 2002PA AC Clamp Meter
Can measure large AC current up to 2000A. 55mm-diameter large tear drop shaped jaws.
Kyoritsu 2002PA Specifications
Functional Specifications | |
Current Ranges | 20 A, 200 A, 200 A, AC RMS |
Output Sensitivity (AC-coupled) | 100 mV, 10 mV, 1 mV, 1 mV per A |
Load Impedance | 100 kΩ minimum |
Accuracy | At 25°C ±1% of range (45 Hz to 65 Hz) |
Linearity | 10% to 100% of range ±0.2% of reading |
Noise | 8mV AC RMS (30 A); 2mV AC RMS (300 A, 3000 A) |
Frequency Range | 10 Hz to 20 kHz (-3 dB) |
Phase Error | < ±1-3/4 (45 Hz to 65 Hz); ± 10 3/4 (at 20 kHz) |
Position Sensitivity | With cable > 25 mm from the coupling ± 2 % of range |
External Field | With Cable > 200 mm from the head ± 1 % of range |
Power Supply | 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator |
Temperature Coefficient | ± 0.08% of reading per °C |
General Specifications | |
Head Circumference | 610 mm (24 in) |
Head Cable Diameter | 14.3 mm (0.56″) |
Head Bend Radius | 38.1 mm (1.5″) |
Cable Length (head to electronics) | 2 m (6.56 ft) |
Output Connection | Molded 4mm safety plugs (not integrated) |
Weight | 180g (6.34 oz) (head); 190 g (6.70 oz) (electronics) |
Safety Standards | EN 61010-1: 2001 EN 61010-2-032: 2002 EN 61010-031: 2002 600 VRMS, Category III, Pollution Degree 2 |
EMC Standards | EN 61326: 1998 +A1, A2, & A3 |
Dimensions | 116 x 68.5 x 30mm (4.56 x 2.69 x 1.18″) |
Reviews